Leancat - Water Electrolyzer Test Station ETS-10

Water Electrolyzer Test Station ETS-10

Leancat’s Water Electrolyzer Test Station ETS-10 is designed for evaluating and characterizing water electrolyzers, specifically those using proton exchange membrane (PEM) and anion exchange membrane (AEM) technologies

Key features:

  • User-Friendly Operation: The ETS-10 allows both manual operation with P&ID visualization and automated operation using an in-house developed Python library.
  • Versatile Testing Capabilities: It can perform a wide range of tests, including JRC standard performance curves, H2 crossover, hydraulic curves, and more.
  • Customizable Options: The station includes wet cathode, nitrogen pre-pressurizing, and simultaneous AEM and PEM testing options.
  • Applications: Researchers use the ETS-10 for material and stack assembly research, efficient stack production, and parameter testing of electrolysers under various conditions.

The Water Electrolyzer Test Station ETS-10 provides a comprehensive platform for studying and optimizing water electrolysis systems. Researchers can explore different operating conditions and evaluate the performance of PEM and AEM electrolysers.

לפרטים נוספים והצעת מחיר, מלא את הפרטים למטה

Specifications

EIS: optional

Max Cathode (Hydrogen) Pressure: 50 barg

Max. Water Temperature: 120°C

Simultaneous AEM and PEM tests: yes

Min. Water Flow: 50 ml/min

Max Anode (Oxygen) Pressure: 50 barg

Wet Cathode: yes

Nitrogen Pressurizing: yes