620 PEM/AEM Water Electrolysis Test Station
תפריט
620 PEM/AEM Water Electrolysis Test Station
620 Electrolyzer Test System (ETS) – A bench-top, fully-integrated instrument for PEM & AEM Water Electrolysis.
- The 620 Electrolyzer Test System (ETS): A bench-top, fully-integrated instrument designed for PEM & AEM Water Electrolysis
- State-of-the-art instrument equipped for comprehensive evaluation and characterization of PEM & AEM water electrolyzers operating with DI water or Alkaline solutions
- Includes an integrated Power Supply, Potentiostat, Impedance Analyzer for EIS & HFR, and real-time sensors for Product Flow Rate and Cross-over Monitoring
- Ideal for laboratories requiring detailed control, diagnostics, and analysis of single-cell PEM or AEM water electrolysis cells
- Powerful FlowCell-ETS® software provides complete control and monitoring of the test cell
- Built-in experiments offer constant, scanning, or step-stair voltage or current-controlled measurements
לפרטים נוספים והצעת מחיר, מלא את הפרטים למטה
מידע נוסף
Scribner 620 Water Electrolysis Test Station Data Sheet
Features
Cell Components
Options
Product support Documents
Features
- 4 current range Potentiostat with ±0.07 / 0.7 / 7 / 20 A, ±5 V, 100 W capabilities
- Programmable Power Supply enabling operation up to 100 A, 5 V, 500 W
- Automated switching between Potentiostat and Power Supply mode
- Integration of mass flow meters for real-time O2 and H2 product flow rate monitoring
- Independent, dual heated liquid feeds for cell positive and negative electrodes
- EIS and HFR available in Potentiostat mode
- EIS data compatible with ZView®, a leading impedance analysis & equivalent circuit modeling software
- Whole cell voltage plus two high-impedance reference electrode inputs for half-cell data
- FlowCell-ETS® application software facilitating complete system control, experiment sequencing, graphing, and data acquisition
- Integrated back pressure maintained to 2 barg
- Compatibility with DI Water and Alkaline Feed Stocks
- N2 purge on Cathode with Supplemental N2 on Anode
- Option for recirculating or single-pass operating mode
- Feed tank level balancing and recirculating capabilities
- Inclusion of an in-line high-temperature Ion Exchange cartridge to ensure DI water purity
- Integration of an 892 Data Expansion Module offering additional 8 temperature + 8 analog inputs, e.g., pressure transducers
- Safety features including E-Stop, Over Voltage/Current, Over Temperature, and Product Gas Cross-Contamination protection
Cell Components
- Flow fields featuring precision machined serpentine or interdigitated flow patterns (custom flow patterns available)
- Gold-plated copper current collectors
- End plates equipped with reactant input/output ports, stainless steel Swagelok® compression fittings, cartridge heaters, and thermocouple wells
- 60 cm (24 in.) heavy-gauge copper conductor load cables
- Includes gaskets, gasket templates, and additional hardware such as bolts, washers, fittings, and O-rings
Options
- Ion Power HYDRION PEM Water Electrolyzer Membrane Electrode Assembly
- SGL Carbon SIGRACET® 25 BC Gas Diffusion Media for Negative (H2) Electrode
- Platinized Titanium porous media for the electrolyzer cell are available from www.fuelcellstore.com
Product support Documents