Ion Chromatography Columns
Columns for the analysis of anions and cations
Shodex columns are known worldwide as the best IC – Carbonate columns in the market.
Shodex Columns fit various Ion Chromatography systems, such as Metrohm and Thermo (dionex).
the columns fit Hydroxide eluent and Carbonate eluent.
Suitable for anion suppressor methods with sodium carbonate eluent
Suitable for the quantitative analysis of fluoride ion
SI-50 4E separates target inorganic anions from organic acids
SI-52 4E provides simultaneous analysis of oxyhalides and general inorganic ions
Carbonate peak does not interfere with analysis
לקבלת ייעוץ ורכישה של קולונות
השאירו כאן את הפרטים:
IC SI-series
Anion analysis for Ion Chromatography suppressor methods with carbonate eluent
IC SI-90 4E
IC SI-50 4E
IC SI-52 4E
IC SI-35 4D
IC SI-35 2B
- Quaternary ammonium groups
- Polyvinyl alcohol particles
- PEEK housing
- Particle sizes of 3.5 µm, 5 µm, or 9 µm
- Suitable for general inorganic ions and oxyhalides
IC SI-36 4D
IC SI-37 4D
Anion analysis for Ion Chromatography suppressor methods with hydroxide eluent
- Quaternary ammonium groups
- Polyvinyl alcohol particles
- PEEK housing
- 3.5 µm particle size
- Effective separation of sulfite and sulfate ions
- Analyzes seven general inorganic anions within 30 minutes under isocratic conditions
- Suitable for NaOH or KOH eluent
IC YS-50
IC YK-421
Cation analysis for Ion Chromatography suppressor and non-suppressor methods
- Carboxyl groups
- Polyvinyl alcohol or silica particles
- Steel housing
- 5 µm particle size
- Suitable for analyzing alkylamines and transition metals
- IC YS-50 offers superior performance compared to IC YK-421
IC NI-424
IC I-524A
Anion analysis for Ion Chromatography non-suppressor methods
- Quaternary ammonium groups
- Polyhydroxymethacrylate particles
- Steel housing
- IC I-524A meets USP L23 requirements
- IC NI-424 offers superior performance compared to IC I-524A
לפרטים נוספים והצעת מחיר, מלא את הפרטים למטה
מידע נוסף
Ion Chromatography
There are two types of Ion Chromatography methods: The suppressor method and non-suppressor method.
Shodex carries columns suitable for both types. As the name tells, the suppressor method uses a suppressor which removes ions that interfere with analytes measurement. The suppressor system is expensive, but some say the sensitivity of suppressor method is superior to non-suppressor method. In contrast, system required for non-suppressor method is cheaper, but the useable solvent is limited to the ones with low conductivity such as phthalic acid.
Suppressor Type Ion Chromatography Column
Shodex IC SI-90 and SI-50 are the suppressor type anion chromatography columns. SI-50 is the higher performance type of SI-90. SI-52 is another suppressor type column suitable for the separation of oxyhalides.
Non-Suppressor Type Ion Chromatography Column
Shodex IC I-524A and NI-424 are the non-suppressor type anion chromatography columns. NI-424 is the higher performance type of I-524A.
Shodex IC YK-421 and YS-50 are the non-suppressor type cation chromatography columns. YS-50 is the higher performance type of YK-421. They can separate both monovalent and divarent cations simultaneously.